Sign In | Join Free | My burrillandco.com
Home > First Aid Equipment >

10.4'' LCD Display Non Invasive Ventilation Machines Gas Drive Electrical Control

    Buy cheap 10.4'' LCD Display Non Invasive Ventilation Machines Gas Drive Electrical Control from wholesalers
     
    Buy cheap 10.4'' LCD Display Non Invasive Ventilation Machines Gas Drive Electrical Control from wholesalers
    • Buy cheap 10.4'' LCD Display Non Invasive Ventilation Machines Gas Drive Electrical Control from wholesalers
    • Buy cheap 10.4'' LCD Display Non Invasive Ventilation Machines Gas Drive Electrical Control from wholesalers

    10.4'' LCD Display Non Invasive Ventilation Machines Gas Drive Electrical Control

    Ask Lasest Price
    Brand Name : MeCan
    Model Number : PA-900BII
    Certification : ISO
    Price : Inquiry
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 500 sets per week
    Delivery Time : 3-15 working dates
    • Product Details
    • Company Profile

    10.4'' LCD Display Non Invasive Ventilation Machines Gas Drive Electrical Control

    Frist Aid Equipment CE Approved 10.4'' LCD Display Ventilator

    Model : PA-900BII

    Prospective service and support

    The PA-900B II ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.

    Display: 10.4''LCD Display Following Parameters & Real time waveform display
    A. ) Gas drive and electrical control, time-pressure switching and pressure limit control.

    B. ) A high-brightness digital display is used to present the control frequency, tidal volume, throughput, overall respiratory rate, spontaneous breathing frequency, etc.

    C ) .A highly sensitive and responsive pressure sensor and a flow sensor are used to measure, control and display the airway pressure and gas flow rate and the ventilator is equipped with automatic throughput compensation.

    D.) In case of an abnormality to the ventilator or misoperation, the ventilator can raise a visual-audible alarm to automatically protect itself

    Ventilator Construction:

    --Environmental Protection Material construction, hardly to be broken.

    -- Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions

    Physical specifications
    Display10.4'' LCD Display
    Mode:pneumatically powered and electrically controlled system
    Working Mode:Closed; Semi-Closed; Semi-Open
    Trolley:Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
    Technical Specifications:
    Gas requirement:Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
    safety valve<12.5 kPa
    Respiratory Rate1bpm~99 bpm
    gas concentration output21% ~ 100% adjustable
    Maximum Minute ventilation≥18L / min, permissible deviation: ±20 %
    Breathing ModeA/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUAL
    Ventilator compliance: ≤30 Ml/kPa
    PEEP:0~1.0KPa
    Ptr:,-1.0~1.0 kPa
    IMV frequency:1 ~ 12 times/min, permissible deviation: ±15%.
    I/E Ratio:4:1~1:4
    Tidal Volume range0~2000ml resolution ratio: 10ml
    Inspiratory Plateau:0~1s
    Maximum Safety Pressure≤ 6.0kPa
    Sigh:one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point and the permissible error is -10% or 15%.
    Pressure limit range:1.0~ 6.0kPa
    Airway pressure alarm: Audible and visual and with yellow and red color indicatingupper alarm: 0.9 kPa ~ 5.4 kPa
    lower: 0.5kPa
    Ventilation Volume alarm:≥ 18L/ MIN
    Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
    Alarm Time: keep >120s
    The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
    Operating conditions
    Ambient temperature:10 ~ 40oC
    Relative humidity:no higher than 80 %
    Atmospheric pressure:860 hPa ~ 1060 hPa
    Power requirement:100-120 Vac, 50/60 Hz;
    Air source requirement:Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.
    Attention: the AC power supply used for the anesthesia machine must be well grounded.
    Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
    Storage
    Ambient temperature:-15oC ~ +50oC
    Relative humidity:no higher than 95 %
    Atmospheric pressure:86 kPa ~ 106 kPa.
     It should be stored in a room without corrosive gas and well ventilated
    Package
    packaging boxcomply with the requirement of GB/T 15464
     Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
     Moisture protection and rain protection to ensure that product is protected from natural damage.
    Safty & Alarm
    Gas source pressureImmediate alarm; “high level alarm” indicator flickers raising an audible alarm.
    Airway Pressure AlarmThe airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm.
    Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle.
    Ventilation Volume AlarmLower: 0~12L/Min; Up: 18L/ Min
    Battery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.
    Power On Self TestSelf test before working, assure it's working normally.